Intra-Aortic Balloon Pumping
"Intra-Aortic Balloon Pumping" is a descriptor in the National Library of Medicine's controlled vocabulary thesaurus,
MeSH (Medical Subject Headings). Descriptors are arranged in a hierarchical structure,
which enables searching at various levels of specificity.
Counterpulsation in which a pumping unit synchronized with the patient's electrocardiogram rapidly fills a balloon in the aorta with helium or carbon dioxide in early diastole and evacuates the balloon at the onset of systole. As the balloon inflates, it raises aortic diastolic pressure, and as it deflates, it lowers aortic systolic pressure. The result is a decrease in left ventricular work and increased myocardial and peripheral perfusion.
| Descriptor ID |
D007423
|
| MeSH Number(s) |
E04.050.215.400
|
| Concept/Terms |
Intra-Aortic Balloon Pumping- Intra-Aortic Balloon Pumping
- Intra Aortic Balloon Pumping
- Intraaortic Balloon Pumping
- Balloon Pumping, Intraaortic
- Pumping, Intraaortic Balloon
- Pumping, Intra-Aortic Balloon
- Balloon Pumping, Intra-Aortic
- Pumping, Intra Aortic Balloon
|
Below are MeSH descriptors whose meaning is more general than "Intra-Aortic Balloon Pumping".
Below are MeSH descriptors whose meaning is more specific than "Intra-Aortic Balloon Pumping".
This graph shows the total number of publications written about "Intra-Aortic Balloon Pumping" by people in this website by year, and whether "Intra-Aortic Balloon Pumping" was a major or minor topic of these publications.
To see the data from this visualization as text,
click here.
| Year | Major Topic | Minor Topic | Total |
|---|
| 2001 | 0 | 1 | 1 |
| 2003 | 0 | 2 | 2 |
| 2005 | 0 | 1 | 1 |
| 2006 | 0 | 1 | 1 |
| 2008 | 0 | 1 | 1 |
| 2009 | 1 | 1 | 2 |
| 2010 | 1 | 1 | 2 |
| 2012 | 1 | 0 | 1 |
| 2013 | 3 | 0 | 3 |
| 2014 | 3 | 0 | 3 |
| 2015 | 1 | 0 | 1 |
| 2019 | 2 | 2 | 4 |
| 2020 | 3 | 0 | 3 |
| 2021 | 1 | 0 | 1 |
| 2022 | 0 | 2 | 2 |
| 2025 | 1 | 0 | 1 |
To return to the timeline,
click here.
Below are the most recent publications written about "Intra-Aortic Balloon Pumping" by people in Profiles.
-
Personalizing Mechanical Circulatory Support for Cardiogenic Shock: A Review and Comparison of Current Devices. Catheter Cardiovasc Interv. 2025 Aug; 106(2):1446-1458.
-
The Use of Mechanical Circulatory Assist Devices for ACS Patients with Cardiogenic Shock and High-Risk PCI. Curr Cardiol Rep. 2022 06; 24(6):699-709.
-
Nephrology Considerations in the Management of Durable and Temporary Mechanical Circulatory Support. Kidney360. 2022 03 31; 3(3):569-579.
-
Extracorporeal Life Support for Cardiogenic Shock With Either a Percutaneous Ventricular Assist Device or an Intra-Aortic Balloon Pump. ASAIO J. 2021 01 01; 67(1):25-31.
-
Percutaneous Left Axillary Artery Placement of Intra-Aortic Balloon Pump in Advanced Heart?Failure Patients. JACC Heart Fail. 2020 04; 8(4):313-323.
-
Waitlist and post-transplant outcomes in patients listed with intra-aortic balloon pump for heart transplant: United Network for Organ Sharing registry. Int J Artif Organs. 2020 Sep; 43(9):606-613.
-
"Do we have to replace the balloon pump when it fails?" Hastings Cent Rep. 2020 Jan; 50(1):10-13.
-
The Man with 2 Hearts: 25 Years from Heterotopic to Orthotopic Heart Transplantation. Tex Heart Inst J. 2019 Jun; 46(3):199-202.
-
Cardiogenic Shock. J Am Heart Assoc. 2019 04 16; 8(8):e011991.
-
Disseminated Cryptococcus neoformans infection in a left ventricular assist device recipient. BMJ Case Rep. 2019 Apr 08; 12(4).