Glaucoma Drainage Implants
"Glaucoma Drainage Implants" is a descriptor in the National Library of Medicine's controlled vocabulary thesaurus,
MeSH (Medical Subject Headings). Descriptors are arranged in a hierarchical structure,
which enables searching at various levels of specificity.
Devices, usually incorporating unidirectional valves, which are surgically inserted in the sclera to maintain normal intraocular pressure.
Descriptor ID |
D020327
|
MeSH Number(s) |
E07.695.250
|
Concept/Terms |
Glaucoma Drainage Implants- Glaucoma Drainage Implants
- Drainage Implant, Glaucoma
- Drainage Implants, Glaucoma
- Glaucoma Drainage Implant
- Implant, Glaucoma Drainage
- Implants, Glaucoma Drainage
- Aqueous Shunts
- Aqueous Shunt
- Shunt, Aqueous
- Shunts, Aqueous
- Glaucoma Filtration Implants
- Filtration Implant, Glaucoma
- Filtration Implants, Glaucoma
- Glaucoma Filtration Implant
- Implant, Glaucoma Filtration
- Implants, Glaucoma Filtration
- Aqueous Humor Shunts
- Aqueous Humor Shunt
- Shunt, Aqueous Humor
- Shunts, Aqueous Humor
|
Below are MeSH descriptors whose meaning is more general than "Glaucoma Drainage Implants".
Below are MeSH descriptors whose meaning is more specific than "Glaucoma Drainage Implants".
This graph shows the total number of publications written about "Glaucoma Drainage Implants" by people in this website by year, and whether "Glaucoma Drainage Implants" was a major or minor topic of these publications.
To see the data from this visualization as text,
click here.
Year | Major Topic | Minor Topic | Total |
---|
2007 | 0 | 1 | 1 |
2017 | 2 | 0 | 2 |
2018 | 1 | 0 | 1 |
2019 | 1 | 0 | 1 |
2020 | 0 | 1 | 1 |
2022 | 2 | 0 | 2 |
2023 | 1 | 0 | 1 |
To return to the timeline,
click here.
Below are the most recent publications written about "Glaucoma Drainage Implants" by people in Profiles.
-
Direct Costs of Second Aqueous Shunt Implant Versus Transscleral Cyclophotocoagulation (The Assists Trial). J Glaucoma. 2023 03 01; 32(3):145-150.
-
Outcomes of the Second Aqueous Shunt Implant Versus Transscleral Cyclophotocoagulation Treatment Study: A Randomized Comparative Trial. J Glaucoma. 2022 09 01; 31(9):701-709.
-
Glaucoma Drainage Device Giant Orbital Reservoir Formation Mimicking Orbital Cyst. Ophthalmic Plast Reconstr Surg. 2022 May-Jun 01; 38(3):e94.
-
Surgical Management of Secondary Pediatric Glaucoma. Int Ophthalmol Clin. 2022 01 01; 62(1):111-130.
-
Reticular Epithelial Edema: An Uncommon Side Effect of ROCK/NET Inhibitor Netarsudil. J Glaucoma. 2020 11; 29(11):e124-e126.
-
Results from the United States cohort of the HORIZON trial of a Schlemm canal microstent to reduce intraocular pressure in primary open-angle glaucoma. J Cataract Refract Surg. 2019 09; 45(9):1305-1315.
-
In Reply: Comparison of Efficacy and Complications of Cyclophotocoagulation and Second Glaucoma Drainage Device After Initial Glaucoma Drainage Device Failure. J Glaucoma. 2018 08; 27(8):e140-e141.
-
Ab Interno Gel Implant for the Treatment of Glaucoma Patients With or Without Prior Glaucoma Surgery: 1-Year Results. J Glaucoma. 2017 Dec; 26(12):1130-1136.
-
Comparison of Efficacy and Complications of Cyclophotocoagulation and Second Glaucoma Drainage Device After Initial Glaucoma Drainage Device Failure. J Glaucoma. 2017 Nov; 26(11):1010-1018.
-
Effect of lowering intraocular pressure on optical coherence tomography measurement of peripapillary retinal nerve fiber layer thickness. Ophthalmology. 2007 Dec; 114(12):2252-8.