Connection

WILLIAM COHN to Time Factors

This is a "connection" page, showing publications WILLIAM COHN has written about Time Factors.
Connection Strength

0.411
  1. Ventricular reconditioning and pump explantation in patients supported by continuous-flow left ventricular assist devices. J Heart Lung Transplant. 2015 Jun; 34(6):766-72.
    View in: PubMed
    Score: 0.056
  2. Technique for aortic valve annuloplasty using an intra-annular "hemispherical" frame. J Thorac Cardiovasc Surg. 2011 Oct; 142(4):933-6.
    View in: PubMed
    Score: 0.044
  3. Right ventricle-sparing left ventricular resection and replacement with a continuous-flow rotary blood pump: an in vivo experiment. Tex Heart Inst J. 2010; 37(3):276-9.
    View in: PubMed
    Score: 0.040
  4. Advances in surgical treatment of acute and chronic coronary artery disease. Tex Heart Inst J. 2010; 37(3):328-30.
    View in: PubMed
    Score: 0.040
  5. Staged reoperation: a novel strategy for high-risk patients. Ann Thorac Surg. 2007 Apr; 83(4):1558-9.
    View in: PubMed
    Score: 0.033
  6. Long-Term Continuous-Flow Biventricular Support in a 63-Year-Old Woman. Tex Heart Inst J. 2018 04; 45(2):110-112.
    View in: PubMed
    Score: 0.018
  7. Bridging to a Long-Term Ventricular Assist Device With Short-Term Mechanical Circulatory Support. Artif Organs. 2018 Jun; 42(6):589-596.
    View in: PubMed
    Score: 0.018
  8. First Implantation of a Novel Left Ventricular Assist Device: The ReliantHeart aVAD. Ann Thorac Surg. 2017 Oct; 104(4):e311-e313.
    View in: PubMed
    Score: 0.017
  9. Tolerance of Sustained Ventricular Fibrillation During Continuous-Flow Left Ventricular Assist Device Support. Tex Heart Inst J. 2017 Oct; 44(5):357-360.
    View in: PubMed
    Score: 0.017
  10. Nonidentical Continuous-Flow Devices For Biventricular Support. Tex Heart Inst J. 2017 Apr; 44(2):141-143.
    View in: PubMed
    Score: 0.017
  11. Surgical approach to continuous-flow left ventricular assist device explantation: A comparison of outcomes. J Thorac Cardiovasc Surg. 2016 Jan; 151(1):192-8.
    View in: PubMed
    Score: 0.015
  12. Effective and rapid sealing of coronary, aortic and atrial suture lines ?. Interact Cardiovasc Thorac Surg. 2015 Jun; 20(6):720-4; discussion 724.
    View in: PubMed
    Score: 0.014
  13. Continuous-flow ventricular assist device exchange is safe and effective in prolonging support time in patients with end-stage heart failure. J Thorac Cardiovasc Surg. 2015 Jan; 149(1):267-75, 278.e1.
    View in: PubMed
    Score: 0.014
  14. Use of sealed grafts in the HeartMate II left ventricular assist device inflow and outflow conduits. ASAIO J. 2014 May-Jun; 60(3):300-3.
    View in: PubMed
    Score: 0.014
  15. Early results after implantation of a new geometric annuloplasty ring for aortic valve repair. Ann Thorac Surg. 2013 Jan; 95(1):94-7.
    View in: PubMed
    Score: 0.012
  16. HeartMate-II left ventricular assist device infections resulting from gastrointestinal-tract fistulas. J Card Surg. 2012 Sep; 27(5):643-5.
    View in: PubMed
    Score: 0.012
  17. Timely use of a CentriMag heart assist device improves survival in postcardiotomy cardiogenic shock. J Card Surg. 2011 Sep; 26(5):548-52.
    View in: PubMed
    Score: 0.011
  18. Continuous-flow total artificial heart supports long-term survival of a calf. Tex Heart Inst J. 2009; 36(6):568-74.
    View in: PubMed
    Score: 0.009
  19. Temporary internal thoracic artery occlusion during off-pump coronary artery bypass grafting with the new poloxamer P407 does not cause endothelial dysfunction. J Thorac Cardiovasc Surg. 2006 Sep; 132(3):685-6.
    View in: PubMed
    Score: 0.008
Connection Strength

The connection strength for concepts is the sum of the scores for each matching publication.

Publication scores are based on many factors, including how long ago they were written and whether the person is a first or senior author.