JACK HOLLADAY to Lens Implantation, Intraocular
This is a "connection" page, showing publications JACK HOLLADAY has written about Lens Implantation, Intraocular.
Connection Strength
4.944
-
Apparent chord mu and actual chord mu and their clinical value. J Cataract Refract Surg. 2019 08; 45(8):1198-1199.
Score: 0.515
-
Improving toric intraocular lens calculations using total surgically induced astigmatism for a 2.5?mm temporal incision. J Cataract Refract Surg. 2019 03; 45(3):272-283.
Score: 0.492
-
Intraocular lens calculations using the Holladay toric calculator. J Cataract Refract Surg. 2016 11; 42(11):1694-1695.
Score: 0.425
-
Influence of ophthalmic viscosurgical devices on intraoperative aberrometry. J Cataract Refract Surg. 2016 07; 42(7):990-4.
Score: 0.416
-
Effect of corneal asphericity and spherical aberration on intraocular lens power calculations. J Cataract Refract Surg. 2015 Jul; 41(7):1553-4.
Score: 0.388
-
July consultation #5. J Cataract Refract Surg. 2013 Jul; 39(7):1125-6.
Score: 0.337
-
Impact of spherical aberration on visual quality and depth of focus. J Cataract Refract Surg. 2024 Jun 01; 50(6):651-652.
Score: 0.180
-
International Intraocular Lens & Implant Registry 2004. J Cataract Refract Surg. 2004 Jan; 30(1):207-29.
Score: 0.175
-
Contemporary statistical analysis of refractive error in adults, pseudophakia, and refractive surgery. J Cataract Refract Surg. 2022 11 01; 48(11):1346.
Score: 0.161
-
Astigmatism analysis and reporting of surgically induced astigmatism and prediction error. J Cataract Refract Surg. 2022 07 01; 48(7):799-812.
Score: 0.157
-
International Intraocular Lens & Implant Registry 2002. J Cataract Refract Surg. 2002 Jan; 28(1):152-74.
Score: 0.152
-
International Intraocular Lens & Implant Registry. J Cataract Refract Surg. 2001 Jan; 27(1):143-64.
Score: 0.142
-
Residual astigmatism with toric intraocular lens misalignment. J Cataract Refract Surg. 2020 08; 46(8):1208-1209.
Score: 0.138
-
Calculation of total surgically induced astigmatism with a toric intraocular lens. J Cataract Refract Surg. 2020 05; 46(5):793-794.
Score: 0.135
-
International Intraocular Lens & Implant Registry 2000. J Cataract Refract Surg. 2000 Jan; 26(1):118-34.
Score: 0.132
-
Pursuing perfection in intraocular lens calculations: IV. Rethinking astigmatism analysis for intraocular lens-based surgery: Suggested terminology, analysis, and standards for outcome reports. J Cataract Refract Surg. 2018 10; 44(10):1169-1174.
Score: 0.121
-
Improved Accuracy With a Vergence-Based Online Toric Intraocular Lens Back-calculator. J Refract Surg. 2018 09 01; 34(9):639.
Score: 0.121
-
Special Report: The American Academy of Ophthalmology Task Force Consensus Statement on Adverse Events with Intraocular Lenses. Ophthalmology. 2017 01; 124(1):142-144.
Score: 0.106
-
Re: Wang et?al.: Comparison of newer intraocular lens power calculation methods for eyes after corneal refractive surgery (Ophthalmology 2015;122:2443-9). Ophthalmology. 2016 09; 123(9):e55-6.
Score: 0.105
-
Negative dysphotopsia: the enigmatic penumbra. J Cataract Refract Surg. 2012 Jul; 38(7):1251-65.
Score: 0.079
-
Argon laser iridoplasty to improve visual function following multifocal intraocular lens implantation. J Refract Surg. 2012 Apr; 28(4):281-3.
Score: 0.077
-
Accuracy of Scheimpflug Holladay equivalent keratometry readings after corneal refractive surgery. J Cataract Refract Surg. 2010 Jan; 36(1):182-3; author reply 183-4.
Score: 0.066
-
Symptoms and Satisfaction Levels Associated with Intraocular Lens Implants in the Monofocal and Premium IOL Patient-Reported Outcome Measure Study. Ophthalmology. 2023 Jul; 130(7):726-734.
Score: 0.042
-
Development of a Patient-Reported Outcome Measure to Assess Symptoms Associated with Cataract Surgery and Intraocular Lens Implants. Ophthalmology. 2023 Jul; 130(7):715-725.
Score: 0.042
-
Use of P1-P4 Purkinje reflections as a surrogate sign for intraoperative patient fixation. J Cataract Refract Surg. 2021 Dec 01; 47(12):e60-e65.
Score: 0.038
-
Rethinking the optimal methods for vector analysis of astigmatism. J Cataract Refract Surg. 2021 01 01; 47(1):100-105.
Score: 0.035
-
Pinhole Pupilloplasty for Higher Order Aberrations: Assessment of Visual Quality and Depth of Focus. J Refract Surg. 2020 Dec 01; 36(12):812-819.
Score: 0.035
-
Comparison of visual performance and satisfaction with a bilateral emmetropic vs a bilateral mild myopic target using a spherical monofocal intraocular lens. J Cataract Refract Surg. 2020 Jun; 46(6):839-843.
Score: 0.034
-
Ultrasonographic measurement of induced myopia associated with capsular bag distention syndrome. Ophthalmology. 2000 May; 107(5):902-8.
Score: 0.034
-
Intraocular lens power calculations in patients with extreme myopia. J Cataract Refract Surg. 2000 May; 26(5):668-74.
Score: 0.034
-
Relationship of the actual thick intraocular lens optic to the thin lens equivalent. Am J Ophthalmol. 1998 Sep; 126(3):339-47.
Score: 0.030